Air quality monitoring
Project
Renovation of a listed building in the center of Paris to house an art collection and the offices of a VIP.
Duration : 1 month
Challenges
The end customer was bothered by a persistent odor in one of the newly renovated offices and could not determine the origin or cause.
Need: monitor air quality and odors
UBY Environment solution
A POD sensor was installed in the office in question and after a one-week training period, we were able to detect the odor variation.
The generated readings allowed us to visualize in time the evolution of this odor variation associated with a formaldehyde peak in the air and to correlate it to the activation of the ventilation.
We could trace the fact that the ventilation ducts had been cleaned with a product containing this chemical compound.
Our case studies
- UBY Environment
Vibration and noise monitoring
Vibration and noise monitoring Project Renovation of an office building for the European Space Agency in the centre of Paris, ...
- UBY Environment
Pawtucket Tunnel project
- UBY Environment
Colas: Les Houches asphalt mixing plant
- UBY Environment
European Community of Alsace
- UBY Environment
Horizon Joint Venture: Grand Paris Express – Section T3A